6-2-1-tekhnicheskie-dannye.html
6.2.1. Specifications
Conclusions of the sensor of a butterfly valve (on the manual transmission)
Conclusions of the sensor of a butterfly valve (on the automatic transmission)
Detonation sensor conclusions
Type |
System of electronic injection of fuel with management from the onboard computer system "Nissan" (ECCS)
|
Codes of engines with fuel injection |
GA14DE (1,4 l) and GA16DE (1,6 l)
|
Idling turns |
|
Fuel pump |
electric, is located in a gasoline tank
|
Fuel pressure at the regulator exit |
about 3,0 bars
|
Data for checks
Resistance of a winding of the fuel pump, |
0,7 Ohm
|
Resistance of the sensor of provision of a butterfly valve |
|
Between conclusions And yes B or 1 and 2: |
– at full closing of the gate |
0,5 kOhm
|
– at partial opening of the gate |
0,5 – 4 kOhm
|
– at full opening of the gate |
about 4 kOhm
|
Nozzle resistance |
10 Ohm
|
Resistance of the perepuskny air valve of stabilization of idling |
10 Ohm
|
Check of a winding of the valve of the proofreader of idling |
When giving food of 12 V on conclusions of a winding the click is listened
|
Sensor of pressure of the hydraulic booster: |
– at turn of a wheel |
contacts of the sensor are opened
|
– the wheel does not turn |
contacts are closed
|
Resistance of the sensor of cooling liquid: |
– at 20 °C |
2,2 – 2,9 Côme
|
– at 90 °C |
0,24 – 0,26 Côme
|
– at 110 °C |
0,14 – 0,15 Côme
|
Only approximate values of resistance are given before recognizing the sensor faulty consult in service of car service.
The recommended gasoline
Cars with catalytic converter |
Unleaded gasoline with octane number 95, filling with ethylated gasoline is forbidden
|
Inhaling moments (N. of m)
Bolts of the case of a butterfly valve: |
– 1st stage |
10
|
– 2nd stage |
20
|
Fuel distributor bolts: |
– 1st stage |
10
|
– 2nd stage |
24
|
Bolts and nuts of the soaking-up collector |
20
|
Bolts and nuts of a final collector |
21
|
Fastening of the exhaust system |
Nuts of fastening of a reception pipe to a collector |
32
|
Bolt of fastening of a reception pipe to an arm |
23
|
Nuts of fastening of a reception pipe to intermediate section (converter) |
49
|
Bolts of fastening of converter to terminal section |
49
|
Bolts of fastening of intermediate section to terminal |
49
|
|
|