7-2-batareya.html
7.2. Battery The battery is in the left part of a motor compartment. Check
PERFORMANCE ORDER |
Standard batteries |
1. At a small run of the car electrolyte density is recommended to check each 3 months. |
2. At suspicion on malfunction of the battery compare electrolyte density in cells which has to differ no more than on 0,04. Otherwise plates are damaged, or there is an electrolyte leak. |
3. If density differs in the specified limits, and the battery is discharged, then it should be loaded. |
Unattended batteries |
4. The condition of the battery is determined by the voltmeter or by the indicator. |
5. The condition of the battery is determined by coloring of the indicator which depends on battery type (consult upon purchase). |
6. When checking tension the voltmeter there have to pass not less than 6 hours after the last trip. Otherwise turn on before check driving beam of headlights on 30 pages. |
7. The battery is completely discharged if tension is lower than 12,2 Century. |
8. Remove the discharged battery and load. |
|
Charging
PERFORMANCE ORDER |
Standard batteries |
1. The battery is charged with the current equal 0,1 from capacity until density of electrolyte does not cease to change within not less than 4 hours. |
2. The battery can also be charged with small current 1,5 A, having left for the night. |
3. The forced charging is not recommended. |
4. Electrolyte temperature at charging should not be above 38 °C. |
Unattended batteries |
5. Batteries of this type demand long charging (up to three days depending on category degree). |
6. Partially discharged battery can be charged with the stabilized source with tension 13,9-14,9 B, within usually 3 hours up to the voltage of 12,5 V. |
7. Completely discharged battery (with tension lower than 12,2 In) is recommended to be charged in a specialized workshop as in the course of a long charge constant control is necessary. |
|
Removal
PERFORMANCE ORDER |
|
1. Turn off nuts and disconnect plugs (arrow) from poles (the first disconnects the negative plug). |
2. Turn off nuts and remove a collar, unhook fastening hairpins. |
3. Remove the battery and a plastic tray. |
|
Installation
PERFORMANCE ORDER |
1. Installation is carried out upside-down. |
2. At first the plug of a positive pole joins, then – negative. |
3. Grease battery poles with technical vaseline. |
|
Electrolyte density
|
It is above 25 °C
|
It is below 25 °C
|
Completely charged battery
|
1,21 – 1,23
|
1,27 – 1,29
|
Loaded for 70%
|
1,17 – 1,19
|
1,23 – 1,25
|
Discharged
|
1,05 – 1,07
|
1,11 – 1,13
|
|
|