1. In process of liquid heating current via the sensor increases and the arrow of the index has to deviate to the right. The faulty sensor should be replaced. |
2. At incorrect indications of temperature check operation of other devices. |
3. If devices do not work, then check a dashboard power-supply circuit. |
4. In case of wrong indications of all devices replace the voltage stabilizer (it is mounted on the printed circuit board of the dashboard). |
5. If only the index of temperature is faulty, then arrive as follows. |
6. In case of the underestimated indications disconnect a wire from the sensor and concern weight. |
7. If at the included ignition of the shooter deviates, then the sensor is faulty. |
8. If indications do not change, then remove the dashboard (see subsection 14.9) and check conducting from the sensor to the index and index food. |
9. If food moves and conducting is correct, then the index is faulty. |
10. In case of the overestimated indications disconnect a wire from the sensor. |
11. If on the cold engine of the shooter deviates in the left part of a scale, then the sensor is faulty. |
12. If indications did not change, then check other part of a chain. |