Service of Nissan Sunny from 1991 to 1997 release in n-14 body.
1. Maintenance instruction
2. Maintenance
3. Engines
4. Cooling system
5. System of heating and ventilation
6. Fuel and exhaust system
6.1. Carburetor engines
6.2. Engines with system of injection of fuel
6.3. System of food / production of the fulfilled gases
6.4. System of decrease in toxicity of the fulfilled gases
6.4.1. Models with 1,4 and 1,6 liter engines
6.4.2. Models with 1,6 and 2,0 liter engines
6.4.2.1. System of decrease in emission of crankcase gases
6.4.2.2. Catalytic converter
6.4.2.3. The control system over release of vapors of fuel from fuel system
6.4.2.4. System of recirculation of exhaust gases
6.4.2.5. System of thermal neutralization
6.4.2.6. System of an admission of air in a final collector
6.4.2.6.1. The operating electromagnetic valve
6.4.2.6.2. Air admission valve
6.4.2.7. System of decrease in toxicity of exhausts
7. System of launch of the engine
8. Coupling
9. Transmissions
10. Half shafts
11. Brakes
12. Suspension brackets and steering
13. Body
14. Electric equipment
 









6-4-2-6-sistema-vpuska-vozdukha-v-vypusknojj-kollektor.html

6.4.2.6. System of an admission of air in a final collector

Check

PERFORMANCE ORDER
1. If you consider that the system is faulty, disconnect hoses from the electromagnetic operating valve of an admission of air and check that they were not littered, having blown them. The electromagnetic valve is located on the left side of an inlet collector, and the valve of an admission of air is located on the left fastening of a forward suspension bracket.
2. The electromagnetic valve can be checked as follows. If you want, the valve can be removed, being guided by the instructions provided in subsection 6.4.2.6.1 for access improvement.
3. Connect the power supply on 12 Volts to the electromagnetic valve, as shown in the drawing for models with the carburetor engine and the catalytic converter. Blow in a branch pipe "And" – air has to pass through the valve and to leave through a branch pipe "In". Blow in a branch pipe "In" and check that through the valve there did not pass air.
4. If the electromagnetic valve does not work as it was expected, so it is faulty, and it needs to be replaced.
5. For valve check of an admission of air, remove it in the beginning, being guided by the instructions provided in subsection 6.4.2.6.2 then, check it as follows.
6. Blow in a branch pipe "In" and check that the valve did not pass air. Pump out air from a branch pipe "And" and blow in a branch pipe "In" – air has to pass through the valve and to leave a branch pipe "With". Blow in a branch pipe "With" and check that air did not pass through the valve in both cases, is on a branch pipe "And" vacuum or not.
7. If the valve does not work as it was expected, so it is faulty, and it needs to be replaced.


6.4.2.5. System of thermal neutralization