6-3-2-11-5-datchik-potoka-vozdukha.html
6.3.2.11.5. Air stream sensor The sensor of a stream of air is installed on the right side of the case of a butterfly valve.
Before its removal, disconnect a wire of the negative plug of the accumulator.
Removal and installation
PERFORMANCE ORDER |
|
1. Disconnect the connection socket from the air stream sensor. |
|
2. Turn off fixing screws (are specified by shooters) and remove the sensor from the case of a butterfly valve and remove its sealing ring (if it is established). |
3. Installation is carried out upside-down removals. At installation use a new sealing ring (if it is established) and reliably tighten fixing screws. |
|
|
|